Engineering. Ingenuity.
Purpose-Built Isolation & Shielding Products for SCIFs and Secure Facilities
EKFox Gear brings fresh engineering perspectives to demanding projects in commercial and government sectors.

Backed Since 1980
A Division of E.K. Fox & Associates
Engineered In-House
Prototyped, Tested & Fabricated in Chantilly, VA
Patented Technology
US-Patented Product Designs
Specification-Ready
Data Sheets & Engineering Files for Every Product
Engineered for Requirements Standard Products Can't Meet
Secure facilities hold their building components to requirements that ordinary commercial products were never designed for. Where HVAC refrigerant and hydronic piping crosses a secure or shielded boundary, that can mean electrical isolation of metallic lines or RF shielding at the wall penetration. EKFox Gear products are engineered specifically for those requirements, and each one comes with the testing data, documentation, and CAD files that MEP engineers, contractors, and security managers need to specify it with confidence.
Our Products for SCIF Piping Penetrations
The Problem We Solve
ICD 705 Requires an Electrical Break. There Was No Commercial Solution.
Intelligence Community Directive 705 requires all metallic lines, including refrigerant lines, crossing a SCIF perimeter to include an electrical break. Without it, copper refrigerant lines create a direct security vulnerability.
EKFox Gear manufactures the only purpose-built HVAC components designed specifically for this requirement, the non-conductive refrigerant line break. Pressure-rated, with UL Recognized Components on select models, and available in 8 sizes manufactured in Chantilly, VA.
The Other Penetration
Hydronic Lines Cross the Boundary Too.
Refrigerant lines aren’t the only metallic penetration in a secure facility. For chilled water, fire protection, and other hydronic lines entering shielded enclosures, the Hydronic Waveguide provides RF-shielded fluid pass-through without compromising the shielded envelope.
Tested shielding effectiveness of 105 dB up to 18 GHz. Complies with NSA 94-106. Suitable for SCIF, MRI room, and RF/EMI test facility penetrations. Available in 3 sizes with standard grooved-end connections.
About EKFox Gear
EKFox Gear is a specialized division of E.K. Fox & Associates focused on developing purpose-built products for complex facility challenges where standard solutions do not exist.
Founded in 2018 and headquartered in Chantilly, Virginia, EKFox Gear combines engineering expertise with prototyping, testing, and fabrication capabilities to develop practical solutions for commercial, government, and high-security facilities.
Our product-focused approach grew from real project needs, including specialized requirements for SCIFs, secure facilities, and other demanding environments. From concept and testing through fabrication, EKFox Gear develops solutions for applications that conventional products cannot address.
Industries We Serve
EKFox Gear products are specified by government contractors, MEP engineers, and installing contractors across the sectors below.

Commercial
Corporate SCIFs, financial trading floors, and high-security commercial facilities require the same isolation standards as government installations.

Government
Government: Federal, DoD, and intelligence community facilities specifying dielectric breaks per ICD 705 and its Technical Specifications.

Data Centers
Secure data centres require electrical isolation of refrigerant lines where they cross shielded zones or security boundaries.

SCIF
Sensitive Compartmented Information Facilities require a dielectric break on all metallic lines crossing the secure perimeter - per ICD 705.
SCIF Penetration FAQs
It depends on the line. Metallic refrigerant lines are typically grounded or fitted with an electrical break, as determined by the facility's CTTA. Hydronic lines passing through RF-shielded construction need a penetration that keeps the shielding intact.
Only if the SCIF has both kinds of penetration. A SCIF served by split-system refrigerant lines would consider the line break where its CTTA calls for electrical isolation. A SCIF with RF-shielded construction and hydronic piping would consider the Hydronic Waveguide. Projects with both conditions may use both.
The facility's Certified TEMPEST Technical Authority (CTTA) determines the required treatment for each project. Grounding and a dielectric break are both accepted methods. Read more on grounding vs. a dielectric break.
The non-conductive refrigerant line break comes in 8 sizes from 1/4" to 1-3/8" OD, covering standard split-system refrigerant line diameters. The Hydronic Waveguide comes in 2", 3" and 4" sizes with grooved-end connections.
Contact Us
Send a message to the team at EKFox Gear, please fill out the form below and click “submit.” Our team will follow up with you as soon as possible.